InstallationandOperationManual(REVH) PVI6500/PVI7500
41
3seconds
↓
3seconds
↓
ThentheLCDwilldisplaythesettingoftheAChighvoltagelimitabovewhichvalue,theinverterwillreducetheoutputpower
untiltheACvoltagedropswithinthissetting.Ifthegridtypeissetto208/240/277VACwithneutral,thedisplaywill
appearas
shownbelow.
3seconds
↓
Then,thesettingofthereconnectiontimewillbedisplayed.Thereconnectiontimeisthedurationofdelaytimefortheinverter
toreconnecttothegridafterthefault(s)is(are)cleared.
3seconds↓
SystemCheckmode
Afterthebasicinformationoftheinverterisdisplayed,thesystementerstheSystemCheckmodewhichisindicatedontheLCD.
Duringthesystemchecking,iftheDCinputvoltagedoesnotreachthepointofthePVstartvoltagesetting,thenthefollowing
messagewillbeshownon
theLCD.ThesystemwillstayinthisstateuntilthePVstartvoltageisreached.
Ifthegridisnotconnectedduringthesystemcheck,theinverterentersthefaultmodeandthefollowingmessagewillbeshown
ontheLCD.
F a c H X X . X X H z
C l r t < X X X C y c s
F a c L X X . X X H z
C l r t < X X X C y c s
V cH Limit
L - N XXX . XV
V p v S t a r t X X X . X V
R e c o n n e c t X X X s
M o de
S y s t e m C h e c k i n g
L o w I n s o l a t i o n
M o de Fault
G r id NA