Candy PVI 7500 Especificações Página 51

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 50
InstallationandOperationManual(REVH) PVI6500/PVI7500

51
GFDIHWError
GFDIdetecthardwarefailure Turnoff theinverterandrestart.
‐IftheerrorreoccursContactinstalling
companyorSolectriaRenewables
IpvH
OvercurrentontheDCside
Useasuitablemeterformeasuring
thecurrentfromthearray.
‐Verifythecurrentiswithinthelimits
fortheinverter.
‐Contacttheinstallingcompanyto
checkthearray
DriverFault
Drivercircuitorpowerdevicefailed
Turnoff theinverterandrestart.
‐IftheerrorreoccursContactinstalling
companyorSolectriaRenewables
CalDataError
Calibrationdataisoutofrange
Turnoff theinverterandrestart.
‐IftheerrorreoccursContactinstalling
companyorSolectriaRenewables
CalDataLoss
Calibrationdataislost.
Turnoff theinverterandrestart.
‐IftheerrorreoccursContactinstalling
companyorSolectriaRenewables
IbuckOver
Internalconverterovercurrent
Turnoff theinverterandrestart.
‐IftheerrorreoccursContactinstalling
companyorSolectriaRenewables
ConverterError DC/DChardwarefailed. Turnoff theinverterandrestart.
‐IftheerrorreoccursContactinstalling
companyorSolectriaRenewables
ModuleTempMax Moduletemperaturehigh Stringsizingdesignprovidestoolow
DCvoltageathighmoduletemperature
5.3 Maintenance:
ReplacingtheGFDIFuse
Beforereplacingthefuse,youmustswitchofftheDC/ACdisconnectswitchandACbreakerandwaitforatleast5minutesfor
systemtodischarge.Verifytheabsenceofvoltagewithavoltmeter.Removethecoveroftheinverterwiringboxandremove
theGFDIfuseholderbypullingthe
holdertowardsyouandthenreplacetheGFDIfusewiththesametypeandrating(600VDC,
1A).
Fig5.3.1ReplacementoftheGFDIfuseholder
1. TurnOFFallDC/ACdisconnectswitches andAC
breaker
2. Waitforatleast5minutes
3. ExchangetheGFDIfuse
4. TurnONallDC/ACdisconnectswitchesandAC
breaker